beautypg.com

Installation, Warning – Lincoln Electric IM355 LN-9F GMA Wire Feeder User Manual

Page 13

background image

INSTALLATION

A-4

A-4

LN-9 GMA and LN-9F GMA Wire Feeder

FIGURE A.2 – STRAIN RELIEF CLAMP

CONNECTING THE POWER INPUT CAbLE
ASSEMbLY TO THE LN-9F CONTROL
bOX

1. See Figure A.3. Connect the polarized plug of the

K196, K595, or K596 control cable to the mating
MS-type connector on the bottom of the LN-9F
GMA control box.

2. Bolt the electrode lead from the power source to the

electrode lead to the wire feed unit using the nut
and bolt supplied. Insulate the connection with elec-
trical tape.

CONNECTING THE POWER INPUT CAbLE
ASSEMbLY TO POWER SOURCES

Turn input supply power to the power source OFF
before connecting the LN-9 GMA or LN-9F GMA wire
feeder.

Connect to an appropriate Lincoln power source as fol-
lows:

1. If using a multipurpose source (such as the DC-

250, DC-400 and DC-600), be sure it is properly
set for the welding process being used. See the
topic "Making a Test Weld," in the Operation sec-
tion of this manual.

For terminal strip connections using the K196 power
input cable, connect the input cable to the power
source exactly as specified on the appropriate LN-9
GMA model connection diagram:

Figure A.4 for DC-250, DC-400 and CV-400, CV-500 l

Figure A.5 for DC-600

Figure A.6 for DC-1000

Figure A.7 for Pulse Power 500

Figure A.8 for R3S-400, R3S-600, R3S-800

FIGURE A.3 – LN-9F GMA CONTROL bOX

bOTTOM VIEW

WARNING

This manual is related to the following products: