INSTALLATION

LN-742 & LN-742H

A-7

GMAW SHIELDING GAS HOOKUP

Gas under pressure is explosive.
Always keep gas cylinders in an
upright position and chained to the
undercarriage or a stationary
support. See American National
Standard Z-49.1,

Safety In Welding

And Cutting

, published by the

American Welding Society.

------------------------------------------------------------------------

Customer must provide a cylinder of shielding gas, a
pressure regulator, a flow control valve, and a hose
from the flow valve to the gas inlet fitting of the LN-742.
Install per Figure A.6 and the following:

1. Connect the supply hose from the gas cylinder

flow valve outlet to the 5/8-18 female inert gas
fitting on the back panel of the LN-742.

2. Install the barbed fitting and union nut to the

5/8-18 female inert gas fitting on the front of the
LN-742. Connect 3/16 in. (4.8 mm) I.D. gas hose
from the gun to the barbed fitting.

When the gun is to be removed, this fitting can be
easily detached by loosening the union nut.

The LN-742 can be used with any shielding gas
recommended in the electrode

s product literature at a

maximum pressure of 60 psi (4.1 bar). This may
include gasses such as Argon, Helium and Nitrogen
and blended gases such as Ar-He, Ar-N2, Ar-O2, Ar-
CO2, CO2, AR-CO2,-O2.

WARNING

FIGURE A.6

SHIELDING GAS HOOKUP.

t

t

GAS

SUPPLY

HOSE

GAS

HOSE

INERT

GAS

FITTING

This manual is related to the following products: