Installation, Safety precautions, Warning – Lincoln Electric IM311 LN-23P User Manual
Page 9: Input cable, Work cable and remote voltage sensing work lead
A-2
INSTALLATION
A-2
LN™-23P
INPUT CABLE
:
For K316L-1 (6 pin connector)
The standard 25 foot input cable between the LN™-
23P and the power source (with a K350 Adapter Kit)
consists of a six-conductor control cable and a 1/0
electrode cable. The control cable has lugged leads
on the power source end and a polarized plug on the
wire feeder end.
With the power source turned off, install the input
cable per the following instructions:
•
Connect the end of the control cable with the
lugged leads to the K350 or K350-1 Adapter Kit.
Connect the electrode cable to the negative output
stud on the power source.
NOTE: If two LN™-23P’s are connected to an
Adapter Kit, connect the feeder that will be used at
the lowest voltage setting to Feeder “A” terminal
strip in the K350. If only one LN™-23P is used,
connect it to Feeder “A” terminal strip.
•
Connect the input control cable polarized plug into
the mating 6 pin receptacle on the rear of the con-
trol section of the LN™-23P. Tighten the threaded
locking collar until the connector is completely
seated.
•
Unclip the rubber retaining strap that holds the wire
enclosure cover in place and remove the cover.
Push the wire drive section door latch towards the
rear of the LN™-23P and open the door. Route the
electrode cable through the large rubber grommet
in the rear of the wire feed section and connect the
lug to the brass conductor block at the front of
motor-gearbox assembly using the bolt provided.
Attach the control cable strain relief hook to the
bracket on the frame of the LN™-23P
.
SAFETY PRECAUTIONS
ELECTRIC SHOCK can kill.
• Only qualified personnel should
perform this installation, maintenance
and troubleshooting work.
• Turn off the input power at the fuse box before
working on other equipment connected to the
welding system at the disconnect switch or fuse
box before working on this equipment.
• Do not touch electrically hot parts.
------------------------------------------------------------------------
WARNING
For K316L-2 or higher (8 pin connector)
With the power source turned off, install the input
cable per the following instructions:
• The K316L-2 LN™-23P can be connected directly to
any Lincoln power source that have CV output and
Twist-Mate weld terminals (V350, V350-PIPE, CV-
305, etc.), using the control cable provided with the
machine.
• Connect the 14-pin connector and Twist-Mate plug
of the input cable assembly to the front of the
welder.
• Unclip the rubber retaining strap that holds the wire
enclosure cover in place, and remove the cover.
Push the wire drive section door latch towards the
rear of the LN™-23P and open the door. Route the
electrode cable through the large rubber grommet in
the rear of the wire feed section and connect the lug
to the brass conductor block at the front of the motor
gear box assembly using the bolt provided. Attach
the control cable strain relief hook to the bracket on
the frame of the LN™-23P.
• Connect the 8-pin receptacle to the LN™-23P locat-
ed on the back underside of the control box.
WORK CABLE AND REMOTE VOLTAGE
SENSING WORK LEAD
•
Connect a work cable of sufficient size and length,
per the following table, between the proper output
stud on the power source and the work. Be sure
the connection to the work makes tight metal to
metal contact.
Above cable sizes are based on a maximum voltage drop of
4.3 volts in the combined lengths of electrode and work
cable at 350 amps.
•
Connect a 12 AWG or larger rubber covered flexi-
ble lead physically suitable for the installation to the
voltage sensing work lead (#21) coming from the
Adapter Kit. For convenience, wrap this voltage
sensing lead around the work lead and tape in
place. Connect it directly to the work or to the work
cable connection . This lead supplies voltage to the
voltmeter as well as power to the LN™-23P control
circuitry and drive motor.
Electrode
Work
Copper
Copper
Cable
Cable
Electrode
Work Cable
Length
Length
Cable Size
Size
0-25 ft.
0-75 ft.
1/0
1/0
0-25
76-125
1/0
2/0
26-75
26-75
2/0
2/0
26-75
76-125
2/0
4/0
76-100
76-125
3/0
4/0