beautypg.com

Warning, Wiring diagram, World's leader in welding and cutting products – Lincoln Electric IM567 K963 Hand Amptrol User Manual

Page 4

background image

NOTE: SINCE THE FULL OUTPUT OF THE CUR-

RENT SETTING IS AVAILABLE WHEN THE
AMPTROL IS FULLY EXTENDED, CARE
MUST BE TAKEN NOT TO SET A CURRENT
WHICH WILL EXCEED THE CURRENT CAR-
RYING CAPACITY OF THE TUNGSTEN.
WHEN IN DOUBT, USE A LOWER CURRENT
SETTING FIRST, THEN INCREASE.

TO AVOID BEING STARTLED BY A HIGH FREQUEN-
CY SHOCK, KEEP THE TIG TORCH AND CABLES IN
GOOD CONDITION.

-

+

POWER SOURCE

6-PIN
PLUG

ELECTRODE LEAD
WORK SENSE LEAD

*

*

}

{

BYPASS

CAPACITOR

KIT

*

{

HI-FREQ KIT
INPUT POWER

*

5-PIN
PLUG

K915-1
AMPTROL
ADAPTER

GROUND
LEAD

6-SOCKET

RECEPTACLE

K963 HAND

AMPTROL

*

SEE INSTRUCTIONS INCLUDED WITH HI-FREQ

KIT FOR CONNECTION INFORMATION.

K799 HI-FREQ KIT

Figure 2- Ground Lead Installation with a K915-1 Adapter

WIRING DIAGRAM

WARNING

• Sales and Service through Subsidiaries and Distributors Worldwide •

Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com

• World's Leader in Welding and Cutting Products •

Copyright © Lincoln Global Inc.

M20516

B

RED

BLACK

ORANGE
WHITE
GREEN

12 PIN
CONNECTOR

A

B

C

D

E

F

G

H

J

K

L

M