beautypg.com

Troubleshooting, Troubleshooting guide, Caution – Lincoln Electric IM796 HANDY MIG 170i User Manual

Page 29

background image

E-3

E-3

TROUBLESHOOTING

TROUBLESHOOTING GUIDE

Observe Safety Guidelines
detailed in the beginning of this manual.

PROBLEMS
(SYMPTOMS)

No wire feed when gun trigger is
pulled. Fan runs, gas flows and
machine has correct open circuit
voltage (33 vcd maximum)

weld

output.

Low or no gas flow when gun
trigger is pulled. Wire feed, weld
output and fan operate normally.

POSSIBLE
CAUSE

1. If the wire drive motor is running

make sure that the correct drive
rolls are installed in the machine.

2. Check for clogged cable liner or

contact tip.

3. Check for proper size cable liner

and contact tip.

1. Check gas supply, flow regulator

and gas hoses.

2. Check gun connection to

machine for obstruction or leaky
seals.

RECOMMENDED
COURSE OF ACTION

If all recommended possible areas
of misadjustments have been
checked and the problem persists,

contact your local Liquid Arc
Authorized Field Service Facility.

FEEDING PROBLEMS

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

LOCAL AUTHORIZED

LIQUID ARC

FIELD SERVICE FACILITY

for assistance before you proceed.

CAUTION

GAS FLOW PROBLEMS

Handymig 170i