beautypg.com

Installation, Caution, A-5 installation of water cooled accessories – Lincoln Electric IM696 COOL ARC 40 STAND ALONE User Manual

Page 11: Figure 2, Figure 3, Figure 4, Figure 5, Cool arc, Water cooled tig torch connection, Water cooled mig gun connection

background image

A-5

INSTALLATION

COOL ARC

®

40

A-5

INSTALLATION OF WATER COOLED
ACCESSORIES

After following the installation instructions above, the
COOL ARC

®

40 is ready for connection to a water-

cooled accessory.

WATER COOLED TIG TORCH AND MIG GUN
Follow Figure 2 when using the COOL ARC

®

40 with

water-cooled TIG torches. Follow Figure 4 when
using the COOL ARC

®

40 with water-cooled MIG gun.

Consult the manufacturer's instruction manual when
using the COOL ARC

®

40 with other water-cooled TIG

and MIG accessories.

CONNECTION TO WIRE FEEDERS
Follow Figure 3
when using the COOL ARC

®

40 in

conjunction with a wire feeder. The feeder will need to
have pass-through water hoses installed in order to
correctly function with the COOL ARC

®

40, since the

cooler requires continuous flow. DO NOT USE A
WATER SOLENOID VALVE with the COOL ARC

®

40.

Water pass-through connection kits are available for
wire feeders. Refer to product literature or the wire
feeder's instructions manual for kit availability and fur-
ther connection details. It is not required to run the
water lines through the wire feeder, but is does pro-
vide a very neat MIG gun connection.If pass-through
water hoses are unavailable, connect the MIG gun as
shown in Figure 4.

DO NOT USE A WATER SOLENOID VALVE with
the COOL ARC

®

40. When a solenoid valve closes,

the pump would dead-head, causing the pump to
heat up excessively leading to premature failure of
the pump.

K529-10 POWER INPUT CABLE WITH WATER
AND GAS HOSES
This cable assembly includes a (1) power cable, (1)
control cable, (1) gas hose and (2) water hoses to
connect a power source to a wire feeder. The cable
length is 10'. The water hoses have 5/8"-18 left hand
male hose fittings and the gas hose has a 5/8"-18
right hand male hose fitting. The cable and hose
lengths are designed to connect a wire feeder to a
COOL ARC

®

40 that is vertically mounted at the rear

of a power source on a dual cylinder undercarriage.
Refer to Figure 5 for an illustration of this connection.

CAUTION

REGULATOR
FLOWMETER

GAS*

ARGON GAS

CYLINDER

COOLANT

OUT

COOLANT

IN

COOLANT*

GAS

COOLANT*

GAS

IN OUT

COOLANT

GAS

TO WORK

POWER / COOLANT

POWER CABLE ADAPTER*

TIG TORCH

*INCLUDED IN

FEMALE TO FEMALE*
CGA FITTING

KP504 HOOK-UP KIT

POWER SOURCE

COOLANT

IN

COOLANT

OUT

COOLANT

COOLANT

GUN CABLE

KP504-WATER HOSES AND

FEMALE TO FEMALE 5/8" LH

CGA ADAPTER COUPLINGS

KP1529-1

FEMALE TO FEMALE 5/8" LH

CGA ADAPTER COUPLINGS

(COUPLINGS ONLY)

SHIELDING

GAS

COOLANT

OUT

NOTE:

ORDER K1859-1 ALONG WITH
K529-10 FOR WIRE FEEDERS
WITH QUICK DISCONNECT
FITTINGS.

COOLANT

COOLANT

GUN CABLE

IN
OUT

K529-10

COOLANT

COOLANT

ELECTRODE CABLE

TO WORK

CONTROL CABLE

COOLANT

IN

NOTE:

BLUE HOSE

RED HOSE

=

COOLANT

OUT

COOLANT

IN

=

COOLANT

IN

COOLANT

OUT

COOLANT

COOLANT

COOLANT

COOLANT

GUN CABLE

NOTE:

COOLANT

OUT

K1859-1 FOR WIRE

FEEDERS WITH QUICK

DISCONNECT FITTINGS

KP504 FOR HOOK-UP

TO WIRE FEEDERS

WITH CGA FITTINGS

COOLANT

IN

=

=

BLUE HOSE

RED HOSE

FIGURE 2

Water Cooled TIG Torch Connection

FIGURE 3

Water Cooled MIG Gun Connection

FIGURE 4

Connection to Wire Feeder (Do Not Use Water Solenoid)

FIGURE 5