F-7

DIAGRAMS

F-7

COMMANDER 400

CONNECTION DIAGRAM:

ELECTRODE

TO WORK

S22914

12-13-96

CAUTION :

AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE

DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

THE ENGINE WELDER OPERATING MANUAL.

N.A. USE VOLTMETER SWITCH TO SELECT DESIRED ELECTRODE POLARITY. POSITION THE RANGE SWITCH TO "WIRE WELDING CV".

APPLICATIONS. SEE OPERATING MANUAL.

N.B. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE

N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE LOCAL REMOTE SWITCH IN "REMOTE" POSITION.

COMMANDER 400 STICK & WIRE / LN-7 CONNECTION DIAGRAM

TO LN-7 INPUT

CABLE PLUG

14 PIN

K584 OR K594CONTROL CABLE

AMPHENOL

OPTIONAL K857

REMOTE CONTROL

6 PIN

AMPHENOL

ELECTRODE CABLE

TO WORK

TO WIRE FEED UNIT

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE

Keep guards in place.

or service this equipment.

Keep away from moving parts.

Only qualified personnel should install,use

Do not touch electrically live parts.

before servicing.

Disconnect NEGATIVE (-) BATTERY LEAD

Do not operate with panels open.

WARNING