E-4

CLASSIC II DEUTZ

E-4

ELECTRONIC IDLER TROUBLESHOOTING GUIDE

Engine Will Not Return To Idle

In Approximately 15 Seconds

Set Idler Control Switch To The

Auto Position

Remove All Weld and Auxiliary

Power Loads

Check Continuity of Idler Control

Switch

Engine Will Not Pick Up Speed When:

1. Check for break in Red

lead and repair.

2. Replace reed switch in

weld circuit.

Replace PC Board

Engine Picks Up Speed

Engine Does Not Pick

Up Speed

Replace P.C. Board

Engine Does Not Pick Up Speed

Check Connections And Continuity

Of Current Transformer

The Auxiliary Power Load Is Turned On

Power Load Too Small

Try Load Above 150 Watts

The Arc Is Struck

Reed Switch In Weld Circuit

Defective - Will Not Close

To Check: Short The Red Lead

On P.C. Board To Welder Frame

Open

Replace Switch

Continuity Good

1. Reed switch in weld circuit may be stuck

closed.

2. Check continuity of idler solenoid coil

(8.5 - 9.0 ohms) & leads.

3. Check ground connections in idle circuit.
4. Replace P.C. Board

TROUBLESHOOTING