beautypg.com

Operation – Lincoln Electric IM731 INVERTEC V350-PRO User Manual

Page 15

background image

B-3

OPERATION

B-3

• The Arc Control regulates the Arc Force to adjust

the short circuit current. The minimum setting (-10)

will produce a "soft" arc and will produce minimal

spatter. The maximum setting (+10) will produce a

"crisp" arc and will minimize electrode sticking.

TIG GTAW: The TIG mode features continuous con-

trol from 5 to 425 amps. The TIG mode can be run in

either the TIG touch start or high frequency (optional

equipment required) assisted start mode.

• The Hot Start control selects the starting mode

desired. A setting of less than 5, the TIG lift start

mode is selected. The OCV is controlled below 10v

and the short circuit "TIG touch" current is main-

tained at 25 amps independent of the preset cur-

rent.

When the tungsten is lifted, an arc is initiated and

the output is regulated at the preset value. Hot start

settings between 0 and 5 regulate the arc initiation

current. A setting of 5 results in the most positive

arc initiation. A setting of 0 reduces hot start.

• Hot Start settings between 5 and 10, select high

frequency assisted starting TIG mode. In this

range, the OCV of the machine is controlled

between 50 and 70 volts. If using the Lincoln K930-

1 TIG Module, set the Hot start to 10 for maximum

OCV.

• The Arc Control is not used in the TIG mode.

TIG SOLENOID OPTION

The Solenoid only operates when th V350 is in the

TIG mode. If the Weld Terminals are in “Remote” then

the solenoid will open when the arc start switch is

closed. The solenoid will close after the arc switch has

been opened and the post flow time expired.

If the Weld Terminals are turned “ON”, then the sole-

noid will open when the electrode is touch to the work.

The electrode needs to remain in contact with the

work to allow for gas coverage before attempting to

start the arc. The solenoid will close after the arc has

been broken and the post flow time expired.

CV-WIRE: The CV-WIRE mode features continuous

control from 10 to 40 volts. The mode was intended

for most GMAW, FCAW, and MCAW applications.

• The Hot Start control is not used in the CV-WIRE

mode.

• The Arc Control regulates pinch effect. At the mini-

mum setting (-10), minimizes pinch and results in a

soft arc. Low pinch settings are preferable for weld-

ing with gas mixes containing mostly inert gases. At

the maximum setting (+10), maximizes pinch effect

and results in a crisp arc. High pinch settings are

preferable for welding FCAW and GMAW with CO2.

INVERTEC® V350-PRO

CV-INNERSHIELD: The CV-INNERSHIELD mode

features continuous control from 10 to 45 volts. This

mode was designed for self-shielded flux cored wires

that require tight voltage control.

• The Hot Start control is not used in the CV-INNER-

SHIELD mode.

• The Arc Control regulates pinch effect. At the mini-

mum setting (-10), minimizes pinch and results in a

soft arc. At the maximum setting (+10), maximizes

pinch effect and results in a crisp arc. Most self-

shielded wires work well at an Arc Control setting of 5.