TERMINAL STRIPS
Terminal strips are available behind the cover on the
case front to connect wire feeder control cables that
do not have a 14 Pin MS-type connector. These termi-
nals supply the connections as shown in the following
Terminal Strip charts. NOTE: There are two work
sense lead connection points on the terminal strip.
Connect both the work sense lead #21 from the 14 pin
connector and #21 lead of the control cable to “-21”
when welding positive polarity or to “+21” when weld-
ing negative polarity.
TERMINAL STRIP 1 (T.S.1)
TERMINAL STRIP 2 (T.S.2)
Lead No.
Function
75
Output Control
76
Output Control
77
Output Control
Lead No.
Function
+21
Work Connection (Electrode Negative)
-21
Work Connection (Electrode Positive)
2
41
42 VAC
4 Trigger
Circuit
2 Trigger
Circuit
31 115
VAC
1
32 115
VAC
1
A-8
INSTALLATION
IDEALARC® DC-600
A-8
AUXILIARY POWER AND
CONTROL CONNECTIONS
Located at the left side of the front of the welder
behind a hinged cover is a 115VAC duplex receptacle
for auxiliary power (60 Hertz Models only). On the right
side of the case front is a 14 Pin MS type receptacle
for connection of auxiliary equipment such as wire
feeders. Also, terminal strips with 115VAC and con-
nections for auxiliary equipment are located behind the
hinged access panel on the right side of the case front.
(see Auxiliary Power Table for details)
115VAC DUPLEX RECEPTACLE (60 HERTZ
MODELS ONLY)
The 115VAC duplex receptacle is protected by a circuit
breaker located on the nameplate. The receptacle is a
NEMA 5-15R.
AUXILIARY POWER TABLE
Voltage and Circuit Breaker Ratings at Auxiliary Power
Connections for Various Models
Auxiliary
60 Hz
50/60 Hz
Power
Models
Models
Connections
At Duplex
115V 15A
No Duplex
Receptacle
Terminal strip
115V 15A
115V 15A
terminals 31 & 32
MS-Receptacle
115V 15A
115V 15A
pins A & J
MS-Receptacle
42V 10A
42V 10A
pins I & K
PIN
LEAD NO.
FUNCTION
A
32
115 VAC
B
GND
Chassis Connection
C
2
Trigger Circuit
D
4
Trigger Circuit
E
77
Output Control
F
76
Output Control
G
75
Output Control
H
21
Work Sense Connection
2
I
41
42 VAC
J
31
115 VAC
1.
K
42
42 VAC
L
---
---
M
---
---
N
---
---
F = 7 6
G = 7 5
H = 2 1
I = 4 1
J = 3 1
K = 4 2
A = 3 2
B = G N D
C = 2
D = 4
E = 7 7
L
N
M
1.
115VAC circuit is on all models.
2.
As shipped from the factory Lead #21 from the 14 Pin connector is
connected to “-21” on the terminal strip (T.S.2). This is the config-
uration for positive welding. If welding negative polarity, connect
lead #21 to the “+21” connection point on the terminal strip
(T.S.2).
14 PIN MS TYPE RECEPTACLE
(For MS3106A-20-27PX Plug. L.E.C. Part #S12020-32)
Refer to the figure A.10 for the available circuits in the
14 pin receptacle.
42 VAC is available at receptacle pins I and K.
A 10 amp circuit breaker protects this circuit.
115 VAC is available at receptacle pins A and J (All
Models). A 15 amp circuit breaker protects this circuit.
Note that the 42 VAC and 115 VAC circuits are electri-
cally isolated from each other.
FIGURE A.10 FRONT VIEW OF 14-PIN
CONNECTOR RECEPTACLE