beautypg.com

Johnson Level & Tool Mfg. 40-6687 User Manual

Page 22

background image

22

©2012 Johnson Level & Tool

7. Perform another self check calibration as described previously to

make sure the laser is calibrated.

8. If the laser is still beyond its accuracy specification, recalibrate the

laser again.

9. If laser is still out of calibration, contact Johnson Level & Tool for

service.

10. Return the plastic screws, being careful not to over-tighten.

Self-checking the 3 Horizontal Beams

1. As shown in Fig. 1, set the instrument on a tripod or flat platform

50’ from an upright wall. Aim the front beam at the face of the
wall. Mark the point projected on the wall by front beam as ‘A’.

2. Turn the instrument clockwise (Fig. 2) to make the point

projected by the right laser beam on the same exact line as point
‘A’, and then mark the point as ‘B’.

3. Turn the instrument clockwise (Fig. 3) to make the point

projected by the left laser beam on the same exact line as point
‘A’, and then mark the point as ‘C’.

4. The vertical distance between points A, B and C should not

exceed 0.125” (3.2mm).

5. If laser exceeds 1/8” at 50’, contact Johnson Level & Tool for

service.

Fig. 1

Fig. 2

Fig. 3

6339H_Manuals 10/24/12 12:56 PM Page 22

This manual is related to the following products: