beautypg.com

Technical specifications, Care and handling – Johnson Level & Tool Mfg. 1455-0000 User Manual

Page 11

background image

©2014 Johnson Level & Tool - Rev. 1 11

7. Technical Specifications

Accuracy:

± 0.1º for 0º and 90º,
and ± 0.2º for all others

Resolution:

0.1º

Working Range:

4 x 90º

Power Supply:

2 “AAA” alkaline batteries (included)

Battery Life:

Approximately 100 hours of
continuous use

Auto Shut Down Time:

After approx. 3 minutes with no movement

Dimensions

6.5" x 2.09" x 0.98"
(165 x 53 x 25 mm)

Weight:

0.529 lbs (0.24Kg)

Working Temperature

37°F to 114°F (5°C to + 50°C)

8. Care and Handling

• Avoid exposing unit to shock vibrations and extreme temperatures.
• Before moving or transporting the unit, make sure that the unit

is turned off.

• Remove the battery when storing the unit for an extended time

(more than three months) to avoid damage to the unit should
the battery deteriorate.

• Avoid getting the unit wet.