Davey QX350P15 (15A) Xcelsior Spa Pool System User Manual
Page 4
P/N Q916962-1
– 3 –
Pump Operation
The Xcelsior’s integrated pump is controlled by just one touch pad button. Pushing the Jet 1
button three times cycles its operation through three modes; Automatic, Manual and Standby.
When the spa is running in automatic mode, pressing the JET 1 button will deactivate auto
mode and set the pump running in Manual Mode. The auto LED is orange when auto mode is
enabled and off when in Manual Mode. When the pump is in standby mode all indicator LED’s
are off.
Push 1 (Manual mode)
Push 2 (Standby mode)
Push 3 (Auto mode)
Note:
1. If pump 1 is left in “Manual” or “Standby” modes, it will automatically revert to “Auto” mode
after 45 minutes.
2. There is no direct user control of the heater. The heater may come on automatically
whenever the pump is on and water heating is required.
Jet 1 button
37.0
FUNCTION
FUNCTION
FUNCTION
– 8 –
Installation & Safety Notes
1.
When installing the Xcelsior Pool System, refer to the appropriate local wiring rules. In
particular refer to AS/NZS 3000:2007 (AS /NZ) and EN60364-4-1 & EN60364-7-1 (EU).
2.
It is recommended that the steel reinforcing in any concrete base on which the pool is
sitting be equipotential bonded to the earth conductor in the supply to the spa. This is to
protect against the possibility of low voltage shocks caused by differential earth voltages.
Refer to the appropriate local wiring rules, e.g. AS/NZS3000:2007 Sections 5.6 & 6.3 or
EN 60364.
3.
Parts containing live parts must be inaccessible to a person in the spa, except parts
supplied with safety extra-low voltage not exceeding 12V (e.g. touch pads and LED lights).
4.
The appliance must be supplied through a residual current device (RCD) having a rated
residual current not exceeding 30mA.
5.
If a supply plug is not fitted or if the system is installed in Europe then the system must be
permanently connected to fixed wiring. Means for disconnection must be provided in the
fixed wiring in accordance with the wiring rules.
6.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent
or similarly qualified persons in order to avoid a hazard.
7.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety. Children should be supervised to ensure that they do not play
with the appliance.
8.
In order to avoid the possibility of hyperthermia (heat stress) occurring, it is recommended
that the average temperature of spa pool water should not exceed 40°C.
9.
The maximum total head for the QX350P10 & QX350P15 is 11m..
10.
The floor or base on which the pool is installed has to be capable of supporting the
expected load.
11.
Precautions should be taken to ensure that spa pool water is disposed of appropriately.
12.
An adequate drainage system should be provided to deal with overflow water.
13.
Precautions should be taken to avoid damage due to water freezing in the pipes and
fittings.
14.
Precautions should be taken to avoid damage when the pool is left empty for an extended
period.