Maintenance continued...

Reverse procedure when replacing sleeve.
When replacing the quartz sleeve after cleaning the sleeve end should protrude

around 4 to 5 mm evenly above the threaded nipple before replacing the o-ring.

More or less than this indicates the sleeve may not be properly located and serious

damage could result when the end-cap is fitted and/or the system is re-

pressurised.
Place o-ring over sleeve and fit end cap with white pressure ring inside it, fastening

it hand tight only.
A tiny amount of silicon spray or CRC in the end of aluminium endcap threads will

aid easy tightening. Do not use excessive force when tightening nuts. Do not re-

use quartz sleeve or o-ring if damaged.

Water Quality

Where the water being pumped contains unusually high levels of dissolved solids

particularly hard water, iron, manganese or biological organisms, a deposit build up

on the quartz sleeve may occur over time. Maximum recommended parameters

are as follows:
Iron:

<0.3 mg/l

Hardness: <120 mg/l

Turbidity: < 1 NTU

Manganese: < 0.05mg/l

Tannins:

< 0.1 mg/l

UVT:

> 75% at 20

o

C

Note: If stated parameters are exceeded pre-filtration is required as water of this

quality can compromise the effectiveness of the UV system. The filters and the

sleeve should be cleaned or replaced as required to maintain them in good

condition. UV transmissibility (UVT) of the water can be tested by your local dealer

or by undertaking an appropriate water test.

Lamp Alarm System

If the UV lamp is out due to a failure or bad connection the alarm buzzer will sound

and the flashing red LED will light continuously. The alarm will disconnect power to

the pump lead preventing untreated water from being delivered. Pressing the

recessed ‘reset’ button once briefly will silence the alarm for 24 hours at a time to

allow checking the connection or lamp replacement and will also reconnect power

to the pump.
The alarm function or lamp can be checked as follows:

1. Switch off mains power to the lamp power supply and remove plug from outlet.

2. Disconnect the lamp.

3. Allow one minute delay to reset the lamp ballast.

4. Reconnect the existing or replacement lamp.

5. Reconnect the power.

The lamp should be replaced after a year’s running time. The alarm will start to

beep intermittently after the internal clock has measured this time as a reminder to

replace the lamp. Pressing the recessed ‘reset’ button briefly with a ballpoint pen

will silence it for 24 hours at a time to allow for a new lamp to be obtained.
Once the new lamp is installed press the ‘reset’ button until the alarm beeps to

start another year’s timing. Do this whenever a new lamp is installed. The red

alarm LED flashes slowly during normal operation to show the timer circuit is

running.