IMPORTANT: When opening the filter housing to install or change the
cartridge (element) it is common for the oring seaI to lift out of the groove
and, at times, it may even stick to the cap.
CAUTION WHEN INSTALLING
1. This is a plastic product with a female thread. If you cross-thread a
male fitting, and/or you over pack with sealing tape, you could do
permanent damage.
2. If you use a tapered thread male fitting do not over tighten.
3. No warranty claims will be considered for damage due to incorrect
installation.
oring into the groove and with two fingers wipe the oring down into the
groove. do not wipe the oring clean of lubricant after it has been properly
seated in the groove because the lubricant prevents “crawling” of the
oring during the tightening of the lid and thus prevents water leaks.
5. screw the housing onto the lid and hand tighten. open the tap
downstream of the filter and then open the inlet valve.
STERIFLO
®
Your new Steriflo
®
system incorporates a lamp failure system design
feature that enables you to be warned of a lamp failure by :-
1. a lamp failure led
2. an audible alarm
3. remote alarm contacts
In addition when the alarm “beeps” on and off, the lamp is due to be
changed so that effective treatment is maintained.
Lamp
Quartz Sleeve (pre-installed in chamber)
Drain plug
Lamp Lead
1 metre
OUTLET
or
INLET
INLET
or
OUTLET
Treatment Chamber
Power Lead
1.5 metre
Alarm LED (Red)
Alarm reset
On LED (Amber)