Once the salt level in the pool is correct the Unit may be switched On. Note: Once the unit starts there
is a short time delay until the cell operates to ensure the filtration system is primed with water) At
this point the Operation LED should be Green; if red refer below. Note: Polarity LED may be either A or B
(whichever is on or brightest.
The RED Operation LED will indicate a number of different possible problem situations:
Possible Problem Action
Salt Level Below Minimum
Add Salt
Cell is Calcified
Clean Cell
Water temperature very cold
Add Salt to compensate for cold water
There is a problem with water flow
Check pump / pipes for blockage or damage. Check that gas sensor is
connected properly
CONTROL PANEL LAYOUT
SELECTOR SWITCH
SANITISER OUTPUT DIAL
OPERATION LED
8:00
6
AM
FUSE
POLARITY
INDICATOR