beautypg.com

Orion-2c pneumatic pressure controller – Condec Orion-2C User Manual

Page 2

background image

© CONDEC 2001 • All rights reserved • Printed in the United States of America • Specifications subject to change without notice

March 2001

63246

Page 2

ORION-2C Pneumatic Pressure Controller

Part #55283, Patent No. 4.698.998

INSTALLATION:

Panel or bracket mounting:

1. Turn the two outside knobs clockwise.

2. Remove all (three) knobs.

3. Install controller into recommended

hole pattern with two
10-32 x 1/2" lg. screws.

4. Install knobs, align set

screws with both
dimples on knob inserts
and shaft.

2.80

1.75

PRESSURE
VALVE

#10-32 UNF-2B
(2) PLACES

FITTING LOCATION
INLET PORT
MS33649-02 THREAD
MATING FITTING, PN 59716

1.82

VENT VALVE

FITTING LOCATION
VENT PORT
MS33649-02 THREAD
MATING FITTING, PN 59716

Model No. Orion 2C
Serial No.
Pressure: 0-3000 psi
Proof Pressure: 3500 psi
Patent No. 4.698.998

TEST PORT#2
MS33649-04 THREAD

6.90

RETAINER PLATE ASSY,
PN 56424
REMOVE AT TIME OF
PANEL MOUNTING

TEST PORT#1
MS33649-02
MATING FITTING, PN 59716 THREAD

VERNIER

2.70

STOP WASHER

LOCK NUT

KNOB INSERT

KNOB

SETSCREW #6-32

5.80

1.53

1.450

2.900

1.450

1.350

Ø .213

(2) PLACES

(2) PLACES

RECECOMMENDED HOLE PATTERN FOR ORION 2