Installation steps, Step 1, Step 2 – Burcam 300828BUP 1/3HP SUB SUMP SYSTEM 115V/12V VERT/MEC SWITCH User Manual

Page 3: Important notice

background image

3

APPLICATION


This submersible sump pump system is designed

for a permanent sump installation.



To be used in a residential cottage and farm application.

FEATURES



Water cooled continuous duty motor.



Thermal and overload protection.



Piggy back grounded cables.



An electrical outlet is required.

CAPACITIES:
(115V AC, 60Hz. 1/3 HP, 7.4A) (15A at start)

5’

2600

10’

2100

15’

1600

20’

250

(12V)



Averrage battery life on a continuous duty cycle:

7 hrs at 4’(1,5m)

4’

1400

9 hrs at 8’ ( 3m)

8’

1200

10 hrs at 10’(4,5m)

10’

1020

INSTALLATION STEPS

We recommend that you install your pump in a clean location where there is adequate

room for servicing at a later date. Protection from freezing temperatures and good

ventilation should be considered as well, to provide the pump an environment for long

life. Do not use to pump gas or toxic fuels. This submersible sump pump is

designed to pump water only.
Friction losses in the discharge pipe must be taken into consideration when the horizontal

offset is greater than 50 feet. The discharge pipe should be increased from 1 1/2” to 2”.

This will reduce friction losses and allow the pump to give maximum performance.
More friction losses must also be taken into consideration when many elbows and

fittings are installed in the discharge line. Each elbows and fittings must be

considered as 1 feet of head.
The float switch of your pump has been pre-set at the factory and does not need any

adjustment.
Never run the pump dry. Damage to the seal may occur. Fill pump pit or sump basin

with water before turning on the power.
Assuming that you have a sump pit located in your basement floor... Your sump pit

must be constructed from concrete, brick, tile or more recently a sump basin made

from plastic and/or fiberglass. The size of your sump pit must be 18” in diameter and

no less than 25” deep. When pit is ready, proceed to next step.

STEP 1

FRICTION

LOSS IN

PIPE NOT

INCLUDED

STEP 2

US GPH

IMPORTANT NOTICE

Please note before you proceed with the installation of this product that

the manufacturer's guideline has to be respected. Failure to comply may

void your warranty.

The following are minimum requirements in order to protect your residence from flooding. It is a small

investment but it is your personal responsibility to protect your home, family and valuables. Failure to comply

with the following requirements may also void your warranty:
- Two (2) pumps have to be installed in the sump pit. The first pump as a primary pump and the second pump

as the backup unit.
- Burcam alarm system model 450454 has to be installed to advise you of any malfunctions.
- As sump pumps are electrically powered and activated so to prevent flooding, a Burcam battery powered

back up pump model 300403 has to be installed to evacuate the water.
Pump selection, proper and adequate installation are a must to comply with local by-laws and need to be

adhered to.

US GPH

ELECTRIC PUMP