Burcam 503721 CONVERTIBLE C.I. JET PUMP 3/4HP 115/230V User Manual
Jet pump
WWW.BURCAM.COM
2190 Boul. Dagenais West
TEL: 514.337.4415
LAVAL (QUEBEC)
FAX: 514.337.4029
CANADA
H7L 5X9 [email protected]
Your pump has been carefully packaged at the factory to prevent
damage during shipping. However, occasional damage may
occur due to rough handling.
Carefully inspect your pump for
damages that could cause failures. Report any damage to your
carrier or your point of purchase.
FACTORY SET VOLTAGE 115 V
CONNECTION VOLTAGE
CHANGING:
Before changing the
voltage connection:
A) Ensure the power to
the pump is disconnected.
B) Open motor junction box cover.
C) Please select the up knob
position for 115V or down
knob position for 230V.
D) Connect to appropriate voltage.
E) Close motor junction box.
INSTALLATION
INSTRUCTIONS
MODELS
503321/503721
AND
OTHER PRODUCTS
503327 503727
503328 503728
503331 503731
ETC.
JET PUMP
Please read these
instructions
carefully.
Failure
to comply to
instructions and
designed
operation of
this system,
may
void
the warranty.
© 2011 BUR-CAM Printed in Canada 510068
Suction connection
Discharge connection
F
low
control
valve
Use the included flow control valve to connect your pump to your home plumbing distribution
pipe system. Install this valve to the pump discharge and close the valve completely by
turning the top screw clockwise. Then, turn the screw counter-clockwise for one turn only
and proceed to the following priming process of the pump.
Follow all these inside step by step instructions to install your pump. Use teflon tape on all
threads. (1) Install the pump discharge fittings as illustrated. (2) Fill the suction line with
water and connect it to the suction inlet. (3) Remove the priming plug and fill the pump body
with water. (4) Screw the plug to the priming inlet. (5) Turn the power on. The pump should
deliver water to the plumbing line within 30
seconds. If not, unplug the pump and repeat the
process at step 3.
After priming the pump, you can adjust the flow
control valve to obtain the best performance of
the pump. Remember that when you open this
valve, you reduce the suction capacity. This
valve is used to balance the discharge flow with
the suction requirement. The deeper your suction
distance, the more closed the valve should be for
optimum performance.
5
2
3-4
1
Priming plug
on the side.