Installation steps, Step 1 step 2, Important notice – Burcam 300527 SUBM SUMP PUMP S. STEEL 3/4HP 115V WITH 20FT CABLE User Manual
Page 3
![background image](/manuals/361773/3/background.png)
3
FEATURES
Non corrosive material.
Stainless steel motor body.
Stainless steel mechanical rotary seal.
Thermal and overload protection.
Piggy back grounded cables
3/4HP, 115VAC, 60Hz, 5.5A, (10A at start).
We recommend that you install your pump in a clean location where there is adequate
room for servicing at a later date. Protection from freezing temperatures and good
ventilation should be considered as well, to provide the pump an environment for
long life. Do not use to pump gas or toxic fuels. This submersible sump pump
is designed to pump water only.
Friction losses in the discharge pipe must be taken into consideration when the hori-
zontal offset is greater than 50 feet. The discharge pipe should be increased from 1
1/2” to 2”. This will reduce friction losses and allow the pump to give
maximum performance.
More friction losses must also be taken into consideration when many elbows and fit-
tings are installed in the discharge line. Each elbows and fittings must be considered
as 1 feet of head.
The float switch of your pump has been pre-set at the factory and does not need any
adjustment.
Never run the pump dry. Damage to the seal may occur. Fill pump pit or sump basin
with water before turning on the power.
Assuming that you have a sump pit located in your basement floor... Your sump pit
must be constructed from concrete, brick, tile or more recently a sump basin made
from plastic and/or fiberglass. The minimum size of your sump pit must be 18” in
diameter and no less than 25” deep. When pit is ready, proceed to next step.
STEP 1
STEP 2
APPLICATION
This submersible sump pump is designed for a
permanent sump installation.
To be used in a residential cottage and
farm application.
CAPACITY:
5’ 4000 USGPH
10’ 3200 USGPH
15’ 2300 USGPH
20’ 1300 USGPH
25’
300 USGPH
INSTALLATION STEPS
FRICTION LOSS
IN PIPE NOT
INCLUDED
IMPORTANT NOTICE
Please note before you proceed with the installation of this product that
the manufacturer's guideline has to be respected. Failure to comply may
void your warranty.
The following are minimum requirements in order to protect your residence from flooding. It is a small
investment but it is your personal responsibility to protect your home, family and valuables. Failure to comply
with the following requirements may also void your warranty:
- Two (2) pumps have to be installed in the sump pit. The first pump as a primary pump and the second pump
as the backup unit.
- Burcam alarm system model 450454 has to be installed to advise you of any malfunctions.
- As sump pumps are electrically powered and activated so to prevent flooding, a Burcam battery powered
back up pump model 300403 has to be installed to evacuate the water.
Pump selection, proper and adequate installation are a must to comply with local by-laws and need to be adhered to.