TROUBLE SHOOTING GUIDE CHECKLIST
NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER
CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER
FROM THE RECEPTACLE.
Switch is off position
Blown fuse
Tripped breaker
Switch port clogged
Defective switch
Defective motor
Improper voltage
Improper voltage
Defective switch
Missing check valve
Clogged check valve in open position
Defective switch
Pump discharge too fast on low head
Water pumped faster than tub is filled
Turn switch to on position
Replace
Reset
Remove and clean switch, port, adaptor
Replace
Replace
Check voltage
Check voltage
Replace
Install valve
Clean debris
Replace
Install ball valve in discharge line to
reduce flow rate
It is normal
TROUBLE PROBABLE CAUSE ACTION
Motor does not
run.
Motor runs but
no water is
delivered.
Pump does not
shut off.
Pump does not
deliver to full
capacity.
Pump starts and
stop too often.