Trouble shooting guide checklist, Trouble probable cause action – Burcam 310100 CONDENSATE WATER PUMP User Manual
Page 6
![background image](/manuals/361755/6/background.png)
FOR INFORMATION TEL: 514.337.4415 FAX: 514.337.4029
6
TROUBLE SHOOTING GUIDE CHECKLIST
NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER
CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER
FROM THE RECEPTACLE
Check the power supply.
No accumulated liquid in basin.
The float mecanism is wedging
The drain line is blocked.
The unit impeller or pump containning
debris.
Float activation is block.
Check valve is blocked or debris on it
Check valve too tight or too loose
O-Ring under check valve is damaged
Check if the appliance generates enough
condensation.
Check to make sure the pump float
mecanism moves freely and clicks the
activation switch when moved and down.
Check the drain line(s) into the pump for
obstructions. Verify for the good condition
working of appliance.
Refer to the maintenance on p.5
Check the tank for debris and clean if
necessary
Check the activation float to be sure it is
not stuck in the up position.
Check the height of the discharge tubing to
be sure it does not exceed 20 vertical feet
Check the dischharge tube or obstructions
and clean if needed.
Check the check valve for obstructions.
Refer to the maintenance on p.5
If the discharge line is plumbed so the
highest point is less than 5 feet above the
pump, the check valvemay allow liquid to
drain out of the line. This is normal and will
not damage the pump.
Check that the valve is hand tight, then
tighten an additional 1/2 turn with 9/16”
wrench.
Replace the O-ring
TROUBLE PROBABLE CAUSE ACTION
Unit does not
run
Liquid drains
back into pump
from discharge
line
Liquid leak
fromm around
the check valve.
The pump
makes loud
noises when
running
Unit runs but
does not pump
liquid out
TO THE END CONSUMER
If you have any problems with the product, before advising the store, where you’ve
purchased the pump, please contact us at 514 337-4415 , and ask for our sales
department, and they will be pleased to help you with any questions you might have,
concerning your installation.