F. ELECTRICAL INFORMATION

1. Electrical Requirements

It is your responsibility to have ALL electrical connections made by a properly licensed and competent
electrician to assure that the electrical installation is adequate and conforms with local and state regulations
or codes. In the absence of such codes, ALL electrical connections, material, and workmanship must
conform
to the applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST
EDITION or in Canada, the Canadian Installation Codes CAN/CGA-B149.1-M91 (Natural Gas) or CAN/
CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION.

IMPORTANT: Failure to comply with these codes or ordinances, and/or the requirements

stipulated in this manual can result in personal injury or component failure.

NOTE: Component failure due to improper installation will VOID THE WARRANTY.

Each dryer should be connected to an independently protected branch circuit. The dryer must be
connected with copper wire only. DO NOT use aluminum wire, which could cause a fire hazard. The
copper conductor wire/cable must be of proper ampacity and insulation in accordance with electric codes
for making ALL service connections.

NOTE: The use of aluminum wire will VOID THE WARRANTY.

NOTE: Wiring diagrams are affixed to the inside at the top front control door and to the rear upper

back guard/panel.