Allied International GX1660C User Manual
Page 10

GX1660 User Manual
70-0057A-A
Allied Vision Technologies (Canada) Inc.
8
SYNC OUTPUTS (1 to 4)
These signals are optically isolated and require the user to provide a high voltage level (USER
VCC) and signal common (USER GROUND). USER VCC can be from 5V to 24V. ICC is a
function of USER VCC and load resistor R. An example of the functional circuit is indicated in
the following diagram.
5V TO 24V
100K
V LOAD
442R
PIN 10. USER VCC
R
VCC-USER
GND-USER
SY NC OUT
USER TRIGGER
CIRCUIT
T4
CAMERA
CIRCUIT
T2
TLP281-4GB
1
2
16
15
T3
IF = 5mA
CAMERA
LOGIC SIGNAL
3.3V CAMERA
LOGIC SIGNAL
SYNC OUT
SIGNAL
T1
Various USER VCC values and load values for the above circuit are indicated in the following
table:
USER
VCC
USER
ICC
R
LOAD
V LOAD
R POWER
DISSIPATION
T1
T2
T3
T4
5V
8mA 500
Ω
4.1V
32mW
1.5µs 6.5µs 2µs 14µs
5V 4.8mA 1K
Ω
4.8V
23mW
1.5µs 5µs 17µs 40µs
12V 9.2mA 1.2K
Ω 11.2V
101mW
1.5µs 11.2µs 2µs 20µs
12V 4.9mA 2.4K
Ω 11.8V
58mW
1.5µs 8.5µs 17µs 55µs
24V 9.5mA 2.4K
Ω 23.2V
217mW
1.5µs 22µs 2µs 37µs
24V 5mA 4.8K
Ω 23.8V
120mW
1.5µs 12µs 17µs 105µs