beautypg.com

MAHLE RTI RHS980H User Manual

Page 11

background image

10

F I L L C Y L C O M P L E T E

A M T F I L L E D # # . # L B

S

T

O

P T

O E

N

D

The Fill Cylinder procedure is complete when desired
amount of refrigerant has been transferred. The Setup
procedure allows changing the value and is covered in
DEFAULT VALUES section in this manual.

Note: To fill to less than 18 LB (8.16 KG), close
valve on cylinder of new refrigerant and allow
procedure to complete. A minimum of 10 LB (4.53
KG) is suggested for truck service application. Do
not manually STOP process with out allowing the
RHS980 to clear the refrigerant from the
accumulator.

REFRIGERANT BLENDS

The RHS980 is designed to recover, recycle and charge R134a. Take extreme precaution to ensure that other
refrigerants are not recovered into the RHS980.

A refrigerant identifier is recommended for evaluating refrigerant in the A/C system prior to servicing.

Recovering other refrigerants will contaminate the refrigerant in the RHS980 charge cylinder.

LEAK SEALERS

Sealants and leak stop chemicals in A/C systems may cause serious damage to the RHS980 if they are present in
the refrigerant recovered intended for recovery.

Detection devices are readily available to check for the presence of these chemicals and are highly recommended
to protect the RHS980.

Call RTI for more information about solutions for detection of refrigerant blends and leak sealers.

This manual is related to the following products: