List of parameters, Important – Yokogawa JUXTA VJRK User Manual
Page 5
5
IM 77J01R21-01E
1st Edition : 2006.08.15-00
11. LIST OF PARAMETERS
No. Item
Display
01
Model
MODEL
02
Tag No.
TAG NO
03
Self-check result
SELF CHK
Display
items
A Display
1
DISPLAY1
A01
Input
value
INPUT1
A05
Output value 1
OUTPUT1
(*1)
A07
Alarm-1 status
ALM1 STATUS
A08
Alarm-2 status
ALM2 STATUS
A54
Status
STATUS
(*2)
A56
Rev No.
REV NO
A58
Menu Rev
MENU REV
A60
Self-check result
SELF CHK
Setting items
(*3)
D Setting
(I/O)
SET(I/O)
D01
Tag no.1
TAG NO.1
D02
Tag no.2
TAG NO.2
D03
Comment
1
COMMENT1
D04
Comment
2
COMMENT2
D07
Input sensor type
SENSOR TYPE
(*1)
D09
RTD
type
RTD
TYPE
D15
Unit
UNIT
D17
Input hard range selection
SELECT RANGE
D22
Input low range
INPUT1 L_RANGE
D23
Input high range
INPUT1 H_RANGE
D30
Burnout
BURN
OUT
D38
Direction of output-1 action
OUT1 DR
(*1)
D60
Self-check result
SELF CHK
Adjusting items
(*3)
P Adjustment
ADJUST1
P01
Wiring resistance correction
WIRING R
P02
Zero adjustment of input 1
ZERO ADJ1
P03
Span adjustment of input 1
SPAN ADJ1
P12
0% adjustment of output 1
OUT1 0%
(*1)
P13
100% adjustment of output 1
OUT1 100%
(*1)
P60
Self-check result
SELF CHK
No. Item
Display
B Display
2
DISPLAY2
B01
Input
value
INPUT1
B05
Output value 1
OUTPUT1
(*1)
B07
Alarm-1 status
ALM1 STATUS
B08
Alarm-2 status
ALM2 STATUS
B60
Self-check result
SELF CHK
E
Setting (alarm output)
SET(ALM)
E01
Alarm-1 setting
SET POINT1
E02
Alarm-2 setting
SET POINT2
E05
Direction of alarm-1 action
ALM1 ACTION
E06
Direction of alarm-2 action
ALM2 ACTION
E07
Alarm-1
hysteresis
HYSTERESIS1
E08
Alarm-2
hysteresis
HYSTERESIS2
E11
Alarm-1 ON delay setting
ON DELAY1
E12
Alarm-2 ON delay setting
ON DELAY2
E13
Alarm-1 OFF delay setting
OFF DELAY1
E14
Alarm-2 OFF delay setting
OFF DELAY2
E15
Direction of alarm-1 relay action
RL1 ACTION
E16
Direction of alarm-2 relay action
RL2 ACTION
E60
Self-check result
SELF CHK
Test items
(*3)
Q Test
TEST
Q02
Forced output 1
OUT1 TEST
(*1)
Q04
Forced output (alarm 1)
ALM1 TEST
Q05
Forced output (alarm 2)
ALM2 TEST
Q60
Self-check result
SELF CHK
*1 : The indications and settings of the parameters are not available.
*2 : The status is displayed for service personnel to see history records.
*3 : To call the parameter setting items D, E, P and Q using the JHT200 Handy Terminal, execute the following operation:
Press F1 ENTER keys.
D, E, P or Q key enters above.
IMPORTANT
Do not change the settings of the items marked “(*1)” in the List of Parameters above after the delivery of the prod-
uct. Doing so may result in a malfunction or a system failure.