Checking the contents of the package, Checking the model name, Tag no. tag no. tag no. tag no – Yokogawa µR20000 User Manual
Page 4: Model and suffix codes
3
IM 04P02B01-51E
Checking the Contents of the Package
Unpack the box and check the contents before operating the software. If some items are
missing or otherwise inconsistent with the contents description, please contact your
dealer or nearest YOKOGAWA dealer.
Checking the Model Name
Check the name plate on the recorder to ensure that the model name and suffix code
match the ones you ordered.
R
C
US
172608
N200
MODEL
SUFFIX
SUPPLY
STYLE
FREQUENCY
NO.
MAC
Made in Chin
a
Do not apply o
il
TAG NO.
TAG NO.
TAG NO.
TAG NO.
R
C
US
172608
N200
MODEL
SUFFIX
SUPPLY
STYLE
FREQUENCY
NO.
MAC
RECORDER
Made in China
Model and Suffix Codes
Model
Suffix Code
-1
-2
-3
Description
µR20000 1 pen recorder
µR20000 2 pen recorder
µR20000 3 pen recorder
µR20000 4 pen recorder
µR20000 6 dot recorder
µR20000 12 dot recorder
µR20000 18 dot recorder
µR20000 24 dot recorder
Japanese
English/German/French & deg F / DST
Chinese & deg F / DST
Alarm output relay 2 points
1
Alarm output relay 4 points
1
Alarm output relay 6 points
1
Alarm output relay 12 points
1,2
Alarm output relay 24 points
1,2
RS-422A/485 interface
3
Ethernet (10BASE-T) interface
3
Fail/Chart end detection and output
2
Clamped input terminal
4
Non-glare door glass
Portable type Power cord UL, CSA st'd
7
Portable type Power cord VDE st'd
7
Portable type Power cord AS st'd
7
Portable type Power cord BS st'd
7
Portable type Power cord GB st'd
7
Mathematical function
Cu10, Cu25 RTD input
3 legs isolated RTD
4,5
Expansion inputs
6
24 VDC/AC power supply
7
Remote control 5 points
Calibration correction
437101
437102
437103
437104
437106
437112
437118
437124
1 /A1, /A2, /A3, /A4, and /A5 cannot be specified simultaneously. /A5 is valid on the dot models.
2 /A5 and /F1 cannot be specified simultaneously on the dot models.
/A4 and /F1 cannot be specified simultaneously on the pen models.
3 /C3 and /C7 cannot be specified simultaneously.
4 /H2 and /N2 cannot be specified simultaneously.
5 Valid only on the dot models.
6 14 types of input including Pt50 RTD, PR40-20, and Platinel TC
7 /H5x and /P1 cannot be specified simultaneously.
/A1
/A2
/A3
/A4
/A5
/C3
/C7
/F1
/H2
/H3
/H5D
/H5F
/H5R
/H5J
/H5H
/M1
/N1
/N2
/N3
/P1
/R1
/CC1
Optional Code