2. SPECIFICATION
General
Display:
LCD, which is continuously powered.
Resettable Total:
7 digits with 10mm (0.4") high digits.
Resettable from front panel.
Accumulated Total:
Displayed when the Accumulated Total button is
pressed.
Rate/Display:
5 digits with 8.5mm (0.33") high digits.
Span:
The units of measure per timebase (eg. gallons/sec) is
programmable in the range 0.000001 to 999,999.
Decimal Points:
Decimal Point positions are fully programmable for
both rate and total.
Timebase:
Span can be programmed in units per second, minute,
hour or day.
Signal Type:
4-20mA.
4-20mA Input
Resolution and
Linearity:
0.05% of span.
Accuracy:
0.05% of span @ 25°C.
0.1% (typ) of span, full temperature range.
Update Time:
0.5 seconds.
Connection:
Two wire.
Voltage Drop:
2.5 volts maximum.
8 Specification