Important – Yokogawa EJX438A User Manual
Page 8
2. Contents of change
(I) Transmitter Mounting (for EJA118E, EJX118A,
EJA438E, and EJX438A)
Please replace the original contents as follows when
the transmitter cannot be installed at least 600 mm
below the HP process connection.
IMPORTANT
The transmitter should be installed at least 600 mm below
the high pressure (HP) process connection to ensure a
positive head pressure of fill fluid. Pay special attention to
vacuum applications.
If it can not be installed at least 600 mm below the HP
process connection, please use the equation below:
h=
× 0.102
[mm]
(P–P0)
ds
h: Vertical height between the HP process connection
and the transmitter (mm)
h≤0: Install the transmitter at least h (mm) below the
HP process connection
h>0: Install the transmitter at most h (mm) above the
HP process connection
P: Pressure in the tank (Pa abs)
P0: Minimum working pressure limit of the transmitter (Pa
abs). See below table.
[For fill fluid code A, B, C, D, E]
Wetted parts
material code
Capillary
length
Process connection size
code
2, 8
3
4,W
SW
1 to 5m
6790
3190
6 to 10m
10030
3520
SE
1 to 5m
6790
3190
6 to 10m
10030
3520
SY
1 to 5m
3190
6 to 10m
3520
HW
1 to 5m
19150
6140
6 to 10m
8290
TW
1 to 5m
9620
3620
6 to 10m
4210
UW
1 to 5m
9540
4750
6 to 10m
6050
[For fill fluid code 1, 2, 4]
Wetted parts
material code
Capillary
length
Process connection size
code
2, 8
3
4,W
SW
1 to 5m
2570
320
6 to 10m
4680
530
SE
1 to 5m
2570
320
6 to 10m
4680
530
SY
1 to 5m
320
6 to 10m
530
HW
1 to 5m
10220
2050
6 to 10m
3450
TW
1 to 5m
4270
570
6 to 10m
960
ds: Specific gravity of fill fluid (at 25°C). See below table.
Fill fluid code A, 1, 4
B
C, 2
D
E
ds: Specific
gravity
1.07
0.94
1.09
1.90 to
1.92
1.09
(II) Capillary Fill Fluid Density Compensation (for
EJA118E, EJX118A, EJA438E, and EJX438A)
Please use the following constant value [B] of fill fluid
for the capillary fill fluid density compensation when fill
fluid code 1, 2, or 4 is specified.
Table A. Constant value [B] of fill fluid
Fill fluid code
1, 2, 4
Constant value [B] mmH
2
O
0.75
Kgf/cm
2
0.0000745
kPa
0.00745
mbar
0.07453
atm
0.000074
inH
2
O
0.02992
psi
0.00108
mmHg
0.05592