User’s manual – Yokogawa EJX440A User Manual
Page 7
User’s
Manual
DPharp
Differential Pressure and
Pressure Transmitters
Manual Change No. 12-023
Oct. 5, 2012
Please correct the information on the following manual as listed below .
IM 01C25T02-01E (12th)
Page and Item
Correct Information
P.2-10
c. ATEX Type of Protection “n”
Note 1.
Applicable Standard:
EN 60079-0:2009, EN 60079-15:2005
P.2-10
c. ATEX Type of Protection “n”
Note 2
Electrical Data
Ui=32 Vdc, Ci=3.52 nF, Li=0 μH
P.2-10
[Installation Diagram]
See the picture ( I ) in below.
P.2-11
(6) Name Plate
See the picture ( II ) in below.
( I )
Non-Hazardous
Locations
Hazardous Locations
[Installation Diagram]
F0209.ai
Terminator
Field Instruments
(Passive)
Hand-
held-
Terminal
(Zone2)
Terminator
Associated
apparatus
U
( II )
Tag plate for type n protection
F0211a.ai
WARNING
Ex nL IIC T4 Gc
ENCLOSURE IP66/IP67
Tamb. -30(-15) to 60°C
MAX. PROCESS TEMP. 120°C
Ui=32V, Ci=3.52nF, Li=0µH
POTENTIAL ELECTROSTATIC CHARTGING HAZARD - SEE USER'S MANUAL.