En g l is h english, Faucet functions maintenance & care – Pfister GT49-YP0Y User Manual
Page 5
![background image](/manuals/359949/5/background.png)
E
N
G
L
IS
H
ENGLISH
ENGLISH
16
17
18
FAUCET FUNCTIONS
MAINTENANCE & CARE
19
CAUTION: Maintenance
DISASSEMBLY
1. Replacement parts may be available at the store where you purchased
your faucet.
2. When replacement parts are not available, please write or call Price
Pfi ster Consumer Service.
3. Always turn off water and relieve pressure before working on your
faucet.
NOTE: Trim Care
Cleaning Instructions:
For all Handles and decorative fi nishes, use only a soft damp
cloth to clean and shine. Use of polish, detergents, abrasive
cleaners, organic solvents or acid may cause damage. Use of
other than a soft damp cloth will nullify our warranty!
Special Trim:
Trim products which contain Porcelain or other similar
substance are not acceptable for public areas or Commercial
use. Installation of Said Trim is at Users Risk!
1–800–PFAUCET (1–800–732–8238)
For Toll-Free Pfaucet information call
1–800–PFAUCET (1–800–732–8238)
or visit www.pricepfi ster.com
• Installation Support
• Care and Warranty Information
16 FAUCET FUNCTION
COLD valve: close-counterclockwise, open-clockwise; HOT valve: close-clockwise,
open-counterclockwise. The Spout (16A) can be rotated around the Faucet Body in
any direction.
Note: Flush faucet before turning on valve (see step 17).
17 FLUSHING & AERATOR CLEANING
After installation is complete, remove Aerator Housing (17A). Turn Valves (17B) on
and allow both hot and cold water to run for at least one minute each. While water is
running, check for leaks. To clean the aerator, disassemble Aerator Housing (17A) by
separating the Aerator Shell (17C), Basket (17D), and Washer (17E). Once parts have
been cleaned, reassemble by reversing steps.
18 VALVE CARTRIDGE REPLACEMENT
Turn off water supplies and relieve pressure before working on your faucet (see
step 2). Remove Handles (18A) and Place Plastic Seal Rings (18B) (see step 10),
unscrew Cartridge Assembly (18C) and inspect. Replace parts as necessary.
19 HOSE CONNECTION REMOVAL
To detach Hose Assembly (19A), remove Clips (19B) from End Valve (19C) and pull
the End Connectors (19D) from End Valves (19C). Remove Center Connector (19E)
by pushing up on Quick Connect Housing (19F). Holding plastic Collet (19G) in place,
pull down on Quick Connect Housing (19F) until Tube (19H) is free.
5
17E
17C
17D
17A
17B
HOT
COLD
OPEN
OPEN
18C
18B
18A
16A
19B
19B
19C
16C
19A
19E
19D
19D
19F
19G
19F
19H
19H