5
2
1
4
3
H
1
2
3
K
2
1
3
L
1
2
J
6
CAUTION: Maintenance
DISASSEMBLY
1. Replacement parts may be available at the store where
you purchased your faucet.
2. When replacement parts are not available, please write or
call Price Pfister Consumer Service.
3. Always turn off water and relieve pressure before
working on your faucet.
NOTE: Trim Care
Cleaning Instructions:
For all Handles and decorative finishes, use only a soft damp
cloth to clean and shine. Use of polish, detergents, abrasive
cleaners, organic solvents or acid may cause damage. Use
of other than a soft damp cloth will nullify our warranty!
Special Trim:
Trim products which contain Porcelain or other similar
substance are not acceptable for public areas or Commercial
use. Installation of Said Trim is at Users Risk!
10 SHOWER ARM AND SHOWER HEAD
INSTALLATION (Fig.H)
Insert the end of Shower Arm (1) through the Shower
Flange (2). Apply PTFE plumber's tape to both ends of
Shower Arm (1) according to manufacturer's instructions.
Screw the long end of Shower Arm (1) into pipe elbow (3)
inside the wall. Slide Shower Flange (2) tight to the wall.
Screw the shower head (4) to the Shower Arm (1), placing
the Washer (5) in between.
11 SPOUT INSTALLATION (Fig.J)
Screw Spout onto (1) Pipe Nipple (2) and tighten until
Spout (2) is properly positioned to the finished wall.
12 UNIT START UP
Turn on hot and cold water supplies, and check all
connections for leaks.
13 CLEANING THE AERATOR (Fig.K)
It is advisable to periodically clean the aerator, in order
to avoid build-up of dirt and limestone, which in time
could gradually limit the water flow. To clean the Aerator,
disassemble Aerator Housing by separating the Aerator
Head (1), Basket (2) and Washer (3). Once parts have been
cleaned, reassemble by reversing steps.
14 CARTRIDGE REMOVAL(Fig.L)
Turn off water supplies and relieve pressure
before working on your faucet! Remove handle
(see step 8). Remove the Dome Cap (1) and Nut (2)
by unscrewing counterclockwise. Carefully remove the
Cartridge (3) by pulling it straight up and out. Reassemble
valve by reversing steps.