16 PLASTERGUARD REPLACEMENT

Replace plasterguard (16A) into Valve Body and secure with Screws (16B).

Proceed to finish wall.

17 FINISH WALL PREPARATION

Make appropriate holes to finished wall. Price Pfister recommends that all Tub

Spout and Shower Outlet holes be 1

1

/

4

” diameter. For center hole on plaster

wall use 4

3

/

4

” diameter.

CAUTION: Make sure that leak tests and flushing are performed before

preparing the finished wall.

18 THIN WALL INSTALLATION

Knock out Center Section (18A) of Plaster Guard (18B) and remove Screws

(18D). For installation of thin walls, use Support Plate (18C) in addition to

Plaster Guard (18B). For installation to other wall types, do not use Support

Plate (18C). Use of Plaster Guard (18B) is optional. For center hole on a thin

wall use 4” diameter.

19 REVERSED INLET LINES

If hot and cold inlets are reversed (back-to-back installation), (19C) unscrew the

plasterguard and bonnet assembly. Rotate the Bonnet Assembly (19A) 180°

with Notch (19B) facing up and reassemble.

NON STANDARD INSTALLATIONS