beautypg.com

English – Pfister GT529-MDS User Manual

Page 4

background image

ENGLISH

ENGLISH

12

14

13

15

16

12 PULL-OUT HOSE ATTACHMENT

From underneath sink, push Quick Connector (12A), located on the end of the Pull-Out

Hose (12B) firmly upward onto the Receiving Tube (12C), until unable to push any

further. Pull down on the Quick Connector (12A). If the housing and the Inner Collet

(12D) separate slightly but do not pull off the Receiving Tube (12C), quick connect is

secure.

13 SOAP DISPENSER INSTALLATION

From above sink, insert threaded Shank (13A) of soap dispenser body through Foam

Gasket (13B) and sink hole. From below sink, tighten Nut (13C) and thread on Soap

Bottle (13D) to Shank (13A).

14 SOAP DISPENSER HEAD INSTALLATION

Pour liquid soap (not included) into the Soap Dispenser Body (14A). Insert Pump

Mechanism (14B) into Soap Dispenser Body (14A). Install Dispenser Head (14C) by

pushing firmly onto Pump Mechanism (14B).

15 WATER SUPPLY CONNECTIONS

Gently separate hot and cold Faucet Inlets (15B), approximately three inches apart.

Connect water Supply Lines (15A) to Faucet Inlets (15B). Hot water supply line goes

to hot inlet fitting indicated by red tag (15C). (Supply lines not included). Follow

manufacturer’s instructions when installing supply lines.

16 SECURING INLET LINES

Do not cross Pull-Out Hose Connection (16A) with Inlet Supply Tubes (16B) to avoid

binding, jamming and interference with the movement of the Pull-Out Hose (16A).

4

16A

15A

12C

13A

12A

12B

12C

12A

12D

12A

13B

13C

13D

14A

14B

14C

15A

15B

15C

15B

HOT

COLD

16B