MACHINE WILL NOT START

Possible causes may be:

1

Foot Pedal not in neutral position (ensure pedal is in neutral position)

2

Foot Pedal neutral position is not correctly set (contact your Nilfi sk-Advance service center)

3

Battery is not connected (connect battery)

4

Machine is out of fuel (refuel)

5

Tripped circuit breaker(s) (reset any tripped circuit breakers)

MACHINE WILL NOT MOVE

Possible causes may be:

1 Parking

Brake

(F) set (release parking brake)

2

Towing Valve in wrong position (set correctly)

3

Tripped circuit breaker(s) (reset any tripped circuit breakers)

MAIN BROOM WILL NOT RUN

Possible causes may be:

1

Debris wrapped around the broom drive (remove debris)

2

Hopper is not completely down (lower hopper completely)

3

Tripped circuit breaker(s) (reset any tripped circuit breakers)

SIDE BROOM WILL NOT RUN

Possible causes may be:

1

Ensure Side Broom OFF switch isn’t selected (push switch to turn ON)

2

Debris wrapped around the broom drive (remove debris)

3

Hopper is not completely down (lower hopper completely)

4

Tripped circuit breaker(s) (reset any tripped circuit breakers)

HOPPER WILL NOT RAISE

Possible causes may be:

1

Tripped circuit breaker(s) (reset any tripped circuit breakers)

HOPPER DUMP DOOR WILL NOT OPEN

Possible causes may be:

1

Dump door jammed by debris (remove debris and clean edges of dirt chamber)

2

Tripped circuit breaker(s) (reset any tripped circuit breakers)

SHAKER MOTOR WILL NOT RUN

Possible causes may be:

1

Tripped circuit breaker(s) (reset any tripped circuit breakers)

DUST CONTROL SYSTEM (IMPELLER) WILL NOT RUN

Possible causes may be:

1

Tripped circuit breaker(s) (reset any tripped circuit breakers)

2

Ensure Dust Control OFF switch isn’t selected (push switch to turn ON)