The FP2500-T42-24V/FP2600-T42-24V units are UL/c-UL listed products (UL File No. E182139).
These units conform as components to the following standards:
UL508
Industrial Control Equipment
UL1604
Electrical Equipment for use in Class 1 & 2 - Division 2, or Class III Hazardous
(classified) locations.
CAN/CSA-C22.2, No.1010-1 Measurement and Control Equipment Safety Requirements for
Electrical Equipment for Measurement and Laboratory
FP2500-T42-24V (UL Registration Model No.:3280033-02)
FP2600-T42-24V (UL Registration Model No.:3280033-04)
•
The FP unit's rear face is not approved as an enclosure. When building the FP unit into an end-use
product, be sure to use an enclosure that satisfies required standards as the end-use product's overall
enclosure.
•
The FP unit must be used indoors only.
•
This unit should be installed in the front face of a metal panel.
•
If the FP unit is installed so as to cool itself naturally, be sure to install it in a vertical panel. Also, be
sure that the FP unit is installed at least 100 mm away from any adjacent structures or machine parts.
If these conditions are not met, the heat generated by the FP unit's internal components may cause the
unit to fail to meet UL standard.
UL1604 Conditions of Acceptability and Handling Cautions:
1. Power, input and output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods
- Article 501- 4(b) of the National Electrical Code, NFPA 70 within the United States, and in
accordance with Section 18-152 of the Canadian Electrical Code for units installed within Canada.
2. Suitable for use in Class I, Division 2, Groups A, B, C and D, Hazardous Locations.
3. WARNING: Explosion hazard - substitution of components may impair suitability for Class I, Divi-
sion 2.
4. WARNING: Explosion hazard - when in hazardous locations, turn power OFF before replacing or
wiring modules.
5. WARNING: Explosion hazard - do not disconnect equipment unless power has been switched
OFF, or the area is known to be non-hazardous.
6. WARNING: Explosion hazard - do not connect/disconnect equipment unless area is known to be
nonhazardous.
UL/c-UL/CSA Application Notes
CE Marking Notes
The FP2500-T42-24V/FP2600-T42-24V units are CE marked products that conform to EMC
directives EN55011 Class A and EN61000-6-2.