beautypg.com

0 troubleshooting en, 0 technical data en – Nilfisk-ALTO Contractor Diesel User Manual

Page 13

background image

14.0 Troubleshooting

EN

Fault

Cause

Repair

The engine fails to start

Insufficient diesel supply

Refill diesel tank.

Battery run down

Recharge the battery*)

Fuse blown

Exchange fuse. See section 3.0.

The pump is frozen

Let the pump thaw.

Working pressure too high

Nozzle partly blocked

Clean the nozzle. See section 12.6.

Working pressure

Valve for regulation of

Open fully the valve for regulation of

too low

water volume is not

water.

adjusted to max pressure

Turn counterclockwise.

Nozzle worn

Replace nozzle.

Motor speed too low

Contact ALTO service technician.

Irregular working

Air in the pump

Repeat the venting procedure.

pressure

Inlet filter/filter blocked

Clean the filter. See section 12.1.

Insufficient water supply

Change to a water supply with greater

from the water works

output. If this is not possible; turn the
valve for regulation of the water volume
clockwise, until the machine works smoothly.

In suction mode:

Excessive suction head

Read section on suction mode (8.4).

or excessively hot water
Nozzle partly blocked

Clean nozzle. See section 12.6.

No working pressure

Nozzle blocked

Clean nozzle. See section 12.6.

No water

Check the water connection.

Unloader (recycling valve)

Allow the machine to thaw.

frozen

See section 10.0.

High pressure hose/

Allow the high pressure hose/

spray lance frozen

spray lance to thaw.

The burner does not

Insufficient fuel supply

Refuel.

ignite

Fuel filter blocked

Clean the filter. See section 12.4

Should faults occur other than those mentioned above, please contact the nearest ALTO service
organization *) IMPORTANT NOTE: To avoid damage to the electronic systems, the battery
connecting cables must be removed when recharging the battery.

15.0 Technical data

EN

Model

CONTRACTOR DIESEL

Pump pressure, max.

bar/psi

180/2610

Water volume at min/max pressure

l/min-USgpm

20,5/19 - 5.42/5

Max. temperature of inlet water

°C/°F

35/95

Heating power

kW/Kcal

115/98.200

Nozzle, spray angle

degrees

(05) 15/65

Self-priming, max. lift

m/ft

5/16.5

Engine

Ruggerini MD 151

Rated effect

kW/hp

12/16.3

Start system

Electric start

Battery

V/Ah

12/50

Diesel consumption, max. pressure

l/h-USgph

3.0-0.79

Fuel consumption at 60°C/140°F

1

)

l/h-USgph

7.5-1.98

“Jerry-can”, capacity

l/Usg

20/5

Sound power level (L

WA

) of the machine measured in accordance with ISO 3746: 112 dB(A).

Sound pressure level (L

PA

) measured in accordance with ISO 11202 [DISTANCE 1m] [FULL LOAD]: 100 dB(A).

1

) Delta t= 52°C/126°F

This machine has been manufactured in accordance with the EMC directive 89/336/EEC inclusive of subsequent
amendments.
Specifications are subject to alterations.