beautypg.com

Rapid-Air PALLET MASTER (PMDH): PMDH35 & PMDH50. 115VAC, 1PH, 60HZ User Manual

Page 2

background image

2

OPERATING INSTRUCTIONS PMD HORIZONTAL

(Revision )

10/1/2002

Warning!!!

Taut Stock (over travel reset) not connected.

Check wiring schematic to connect interface with material pulling device.

INSTALLATION
1. The machine that you have just received is fully assembled and ready to be put into posi-

tion. Due to shipment vibration the machine should be checked to be sure all screws and
bolts are tight and that all electrical components are in place inside cabinet. Visually in-
spect the machine for damaged parts due to shipment. If the machine was damaged in ship-
ment, contact the carrier first to report the damage, and then Rapid-Air.


2. Install the machine on a level surface with sufficient clearance for loading and unloading

coils.


3. The machine is completely self-contained and need only be plugged into a 20 amp, 120 volt,

60 HZ outlet. If an extension cord is used as the source to the machine, it should be a mini-
mum #12 gauge wire to keep the voltage loss down and for electrical safety reasons.


See Drawing Below