Rapid-Air CABINET REEL: 15, 25, 40 & 60 SERIES User Manual
Page 5

9. LOOP ARM/ARM EXTERNAL SWITCH
This switch selects either dancer arm (internal ) or “D” connector (external) speed
control functions.
10. RESET BUTTONS
a. 15 amp - This is the main circuit breaker for the reel.
b. 3 amp - this is the circuit protection for the “D” connector. Any shorts or over
loads would trip this breaker.
11. REMOTE INTERFACE PORT “D” CONNECTOR
This connector is used to communicate with external loop control equipment.
CAUTION: Never plug any type of computer or non Rapid-Air equipment into this
plug or severe damage will result. Always consult with the factory when installing
new external controls for compatibility and wiring information.
ELECTRICAL COMPONENT DESCRIPTION
69100034 board - proportional control board
69100076 board - component interface board
69100014 Motor control board (RAMM) - D.C. motor board
69100196 Motor control board (KBRG) - D.C. motor board
69100185 Motor control board (KBRG) - D.C. motor board 3 hp