Rapid-Air CABINET REEL: 15, 25, 40 & 60 SERIES User Manual
Page 10

TROUBLE SHOOTING GUIDE
MAIN SWITCH ON BUT NOT LIT
1. CB tripped
a. Reset CB
2. Unit not plugged into main power
a. Plug into main power source
3. No power in incoming line.
a. Check outlet.
b. Check power cord.
4. Loose wiring
a. Check terminals and connections.
MOTOR CREEPS IN STOP POSITION
1. R1 & R3 pot on 69100034 board not correctly adjusted.
a. Reajust pots so table stops. Call factory.
2. Dancer arm bent.
a. Readjust R1 & R3 on 61000033 board.
b. Straighten dancer arm.
UNIT TURNS ON BUT WON”T JOG
1. Selector switchnot in jog position.
a. Select jog.
2. Jog pot on 69100076 board not adjusted correctly.
a. Adjust pot on 69100075 board. Call Factory.
3. Maximum speed pot on Ramm board set too low.
a. Adjust pot.
UNIT ON BUT MOTOR WON’T RUN. (ARMATURE VOLTAGE PRESENT - ON
RAMM BOARD)
1. Check motor wiring and fuse.
a. Replace motor cord or correct motor wiring. Call Factory.
2. Check motor.
a. Worn brushes or motor defective. Call Factory.
UNIT ON BUT MOTOR WON’T RUN. (NO ARMATURE VOLTAGE ON RAMM
BOARD)
1. Selector switch not in run position.
a. Turn selector switch to run position.
2. If running with a dancer arm control.
a. Check that the external/loop arm switch is in the external position.
3. If running with external control.
a. Check that the external/loop arm switch is in the external position.
4. Height switch setting too high.
a. Set height setting to “O”.
5. Percent speed pot set too low.
a. Adjust percent speed pot to 100%.