beautypg.com

Installation – Lincoln Electric IM10026 TOMAHAWK 1000 User Manual

Page 8

background image

A-1

INSTALLATION

A-1

Weight

Including

Torch Cable

63.9 lbs.

29 kgs

INPUT - SINGLE PHASE/THREE PHASE/ 50 / 60 HERTZ

RATED OUTPUT AT 40° C

OUTPUT

RECOMMEND INPUT WIRE

REQUIRED GAS FLOW RATE

REQUIRED GAS INLET PRESSURE

PHYSICAL DIMENSIONS

TECHNICAL SPECIFICATIONS -TOMAHAWK™ 1000

Input Voltage +/- 10%

Duty Cycle

100%

50%

Current

Range

20 - 60 Amps

#10 (5.3 mm

2

)

Input Supply Wires 1 Ground Wire

#10 (5.3 mm

2

)

Type S, SO, ST, STO

or Extra Hard Usage Cord

AWG (IEC) Sizes

Depth

21.65 in.

550 mm

Width

9.7 in.

247 mm

Height

15.3 in.

389 mm

Open Circuit

Voltage

270 VDC

For all plasma cutting applications

Based on U.S. National Electrical Code

Ambient Temperature 30

o

C or Less

Pilot Current

20 Amps

CURRENT

40A

60A

VOLTAGE

96VDC

104 VDC

208V/1/50/60

230V/1/50/60

208V/3/50/60

230V/3/50/60

460V/3/50/60

575V/3/50/60

Input Amperes @ Rated Output

Circuit Breaker (Delay Type)

38
25

50% Duty Cycle

100% Duty Cycle

34
23

50% Duty Cycle

100% Duty Cycle

25
16

50% Duty Cycle

100% Duty Cycle

21
13

50% Duty Cycle

100% Duty Cycle

9
6

50% Duty Cycle

100% Duty Cycle

8
5

50% Duty Cycle

100% Duty Cycle

40 Amps

30 Amps

15 Amps

80.0 PSI @ 275 SCFH

(5.5 Bar. @ 130 ±20% LITERS/MIN.)

87.0 to 109.0 PSI

(6.0 Bar. to 7.5 Bar.)

STO, 600V

Input Cord

Supplied with Machine

TOMAHAWK™ 1000

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE

-10°C to +40°C

STORAGE TEMPERATURE RANGE

-25°C to +55°C