beautypg.com

Installation, Gas input connections, Output connections – Lincoln Electric IM10015 TOMAHAWK 375 AIR User Manual

Page 10: Warning

background image

A-3

INSTALLATION

TOMAHAWK™ 375 AIR

A-3

The following Lincoln engine drives meet these condi-
tions when run in the high idle mode:

Outback 180, Ranger 225, 250, 250LPG, 305G and
305D engine drives.
Vantage 300, 400, 500 and Air Vantage engine drives.

Operation of the TOMAHAWK™ 375 AIR is not rec-
ommended on engine drives not conforming to these
conditions. Such combinations may overvoltage the
TOMAHAWK™ 375 AIR power source.

GAS INPUT CONNECTIONS

(External Air Supply)

Supply the TOMAHAWK™ 375 AIR with clean com-
pressed air or nitrogen.

Supply pressure must be between 80 psi
and 110 psi.

Flow rate should be approximately 125 - 200
SCFH (80 ±20 L/min).

NOTE: Oil in the air supply to the TOMAHAWK™ 375

AIR can cause severe problems. Use only a
clean air supply.

• Compressed gas can be supplied either through the air

fitting supplied with the machine or through the 1/4

-

19

BSPP

thread at the rear of the machine. To use the air

fitting supplied with the machine (packaged in the con-
sumable kit), apply teflon tape to the fitting threads and
install the fitting in the port at the rear of the machine.

• If compressed air is being used, it is highly recom-

mended that an in line filter be installed in the air
supply line ahead of the air connection to the TOMA-
HAWK™ 375 AIR.

• A standard nominal 5 micron in line filter is recom-

mended; however, for optimum performance, select
a prefilter with a 3 micron absolute rating.

If these filter ratings are unavailable, anything with a
rating less than, or equal to, 20 micron would be
acceptable to use. In line filter elements will generally
filter the air with little restriction to the airflow until the
element is about 75% contaminated. After this point,
there will be a noticeable pressure drop in the line.
Filter elements should be replaced when a pressure
drop of 8-10 psi is indicated; however, for optimum
performance of the TOMAHAWK™ 375 AIR, the filter
element should be replaced at or before the pressure
drop reaches 8 psi. Be sure to select a filter that will
accommodate the necessary flow rating for the TOM-
AHAWK™ 375 AIR as specified in the Installation sec-
tion of this instruction manual under the Gas Input
Connections heading.

NOTE: When using nitrogen gas from a cylinder, the

cylinder must have a pressure regulator.

Maximum psi from a nitrogen gas cylinder to
the TOMAHAWK™ 375 AIR regulator should
never exceed 110 psi.

Install a hose between the nitrogen gas cylin-
der regulator and the TOMAHAWK™ 375 AIR
gas inlet.

CYLINDER could explode if damaged.

• Keep cylinder upright and

chained to a fixed support.

• Keep cylinder away from areas

where it could be damaged.

• Never lift machine with cylinder

attached.

Never allow the cutting torch to touch the
cylinder.

Keep cylinder away from live electrical
parts.

Maximum inlet pressure 110 psi.

------------------------------------------------------------------------

OUTPUT CONNECTIONS

Torch

The TOMAHAWK™ 375 AIR is sent from the factory
with a cutting torch and work clamp installed. The
work clamp must be securely connected to the work
piece. If the work piece is painted or extremely dirty it
may be necessary to expose the bare metal in order
to make a good electrical connection.

Built-In Compressor
This machine has a built-in compressor that allows
operation in areas where an air supply is not avail-
able. Only input voltage is necessary! The compres-
sor provides a fixed pressure.

Read and understand this entire section before oper-
ating the machine.

WARNING