background image

E-4

TROubLEShOOTING

E-4

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAuTION

PRObLEMS

(SYMPTOMS)

POSSIbLE

CAuSE

RECOMMENDED

COuRSE OF ACTION

Engine does not start.

Irregular running of the engine.

1. Faulty Ignition switch and or

Injector pump solenoid. Correct
the connection and contact.

2. Insufficient charging or complete dis-

charge of the battery. Charge.

3. Lack of fuel. Supply fuel.

4. Air mixed in the fuel system.

5. Clogged fuel filter. Replace.

6. Irregular and faulty fuel supply

(Injector pump trouble). Repair in
an authorized field service shop.

7. Glow plug not heated. Breakage

of the glow plug; replace.

8. Improper viscosity of the lubricat-

ing oil. Inspect and replace.

9. Clogged air cleaner. Clean or

replace.

10. No compression. Repair in a field

service shop.

1. Air mixed in the fuel system.

2. Uneven fuel injection (Faulty fuel

injector pump). Repair in an
authorized field service shop.

3. Clogged fuel filter. Replace.

4. Defective governor. Check and

correct.

5. Engine itself defective. Repair in

an authorized field service shop.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Authorized Field
Service Facility.

D300K 3+3 SE

ENGINE TROubLEShOOTING