beautypg.com

Operation, B-4 welding process – Lincoln Electric IM10052 RANGER 250 GXT (AU) User Manual

Page 18

background image

B-4

OPERATION

B-4

WELDING PROCESS

For any electrodes the procedures should be kept within
the rating of the machine. For electrode information see
the appropriate Lincoln publication.

STICK (CONSTANT CURRENT) WELDING

Connect welding cables to the "TO WORK” and "ELEC-
TRODE” studs. Start the engine. Set the "Polarity” switch
to the desired polarity. The “RANGE” switch markings
indicate the maximum current for that range as well as
the typical electrode size for that range. The “OUTPUT”
Control provides fine adjustment of the welding current
within the select range. For maximum output within a
selected range set the “OUTPUT” Control at 10. For min-
imum output within a selected range set the “OUTPUT”
Control at 5. (“OUTPUT” Control settings below 5 may
reduce arc stability) For best overall welding perfor-
mance set the “RANGE” Switch to the lowest setting and
the OUTPUT” Control near the maximum to achieve the
desired welding current.

RANGE SETTING

TYPICAL

CURRENT RANGE

ELECTRODE SIZE

The Ranger® 250 GXT (AU) can be used with a broad
range of AC and DC stick electrodes. See “Welding Tips
1” included with the Ranger® 250 GXT (AU) for elec-
trodes within the rating of this unit and recommended
welding currents of each.

TIG (CONSTANT CURRENT) WELDING

The Ranger® 250 GXT (AU) can be used in a wide variety of
AC and DC Tungsten Inert Gas (TIG) welding applications for
AC TIG Welding up to 200 amps and DC TIG welding up to 250
amps.

The K930 [ ] TIG Module installed on a Ranger® 250 GXT
(AU) provides high frequency and shielding gas control for AC
and DC GTAW (TIG) welding processes. The TIG Module
allows full range output control.

When using the Ranger® 250 GXT (AU) for AC TIG welding of
aluminum the following settings and electrodes are recommend-
ed:

For AC TIG Welding, the maximum TIG Welding out-
put currents on each range setting will be approxi-
mately 50% higher than those marked on the name-
plate. This is due to the special nature of the AC TIG
welding arc. Do not AC TIG weld on the 250 Amp set-
ting. The output may exceed the rating of the
Ranger® 250 GXT (AU).

WIRE FEED WELDING PROCESSES
(CONSTANT VOLTAGE)

The Innershield

®

electrode recommended for use with

the Ranger® 250 GXT (AU) is NR

®

-211-MP. The elec-

trode sizes and welding ranges that can be used with
the Ranger® 250 GXT (AU) are shown in the following
table:

The Ranger® 250 GXT (AU) is recommended for lim-
ited “MIG” welding (GMAW - gas metal arc welding).
The recommended electrodes are .030” and .035” L-
50 and L-56. They must be used with a blended
shielding gas such as C25 (75% Argon - 25% CO

2

).

The welding ranges that can be used with the
Ranger® 250 GXT (AU) are shown in the following
table:

ARC GOUGING

The Ranger® 250 GXT (AU) can be used for limited
arc gouging.

Set the Range switch to adjust output current to the
desired level for the gouging electrode being used
according to the ratings in the following table:

RANGER® 250 GXT (AU)

Diameter Wire Speed Approximate

(in.) Range In./Min. Current Range

.035

80 - 110

75A to 120A

.045

70 - 130

120A to 170A

.068

40 - 90

125A to 210A

5/64

50 - 75

180A to 235A

Diameter Wire Speed Approximate

(in.) Range In./Min. Current Range

.030

75 - 300

50A to 130A

.035

100 - 250

80A to 175A

.045

125 - 200

145A to 200A

SETTINGS FOR PURE TUNGSTEN

TUNGSTEN RANGE SWITCH

APPROXIMATE

DIAMETER (in.) SETTINGS CURRENT RANGE

1/8 80 or 130 100 - 300 Amps

3/32 80 45 - 140 Amps
1/16 80

45 - 100 Amps

SETTINGS FOR  1% THORIATED TUNGSTEN

TUNGSTEN RANGE SWITCH

APPROXIMATE

DIAMETER (in.) SETTINGS CURRENT RANGE

1/8 80, 130, or 180 80 - 225 Amps

3/32 80 or 130 50 - 180 Amps
1/16 80 45 - 120 Amps

ELECTRODE SETTING CURRENT RANGE (DC, electrode positive)

1/8 30 - 60 Amps

5/32 90 - 150 Amps
3/16 150 - 250 Amps

80 MAX.

130 MAX.

180 MAX.

250 MAX.

3/32

1/8

5/32

3/16

50 TO 80 AMPS

70 TO 130 AMPS

110 TO 180 AMPS

160 TO 250 AMPS