beautypg.com

Operation – Lincoln Electric IM10017 RANGER 225 User Manual

Page 20

background image

B-5

OPERATION

B-5

RANGER® 225

WIRE FEED WELDING PROCESSES
(CONSTANT VOLTAGE)

The Innershield

®

electrode recommended for use with

the RANGER® 225 is NR

®

-211-MP. The electrode

sizes and welding ranges that can be used with the
RANGER® 225 are shown in the following table:

The RANGER® 225 is recommended for limited “MIG”
welding (GMAW - gas metal arc welding). The recom-
mended electrodes are .030” and .035” L-50 and L-56.
They must be used with a blended shielding gas such
as C25 (75% Argon - 25% CO

2

). The welding ranges

that can be used with the RANGER® 225 are shown
in the following table:

Diameter Wire Speed Approximate

(in.) Range In./Min. Current Range

.035

80 - 110

75A to 120A

.045

70 - 130

120A to 170A

.068

40 - 90

125A to 225A

Diameter Wire Speed Approximate

(in.) Range In./Min. Current Range

.030

75 - 300

50A to 130A

.035

100 - 250

90A to 175A

SUMMARY OF WELDING PROCESSES

CONTROL ELECTRODE

CABLE IDLE WHEN NOT TO START

PROCESS USED MODE WELDING WELDING

ELECTRODE SETTING CURRENT RANGE (DC, electrode positive)

1/8 30 - 60 Amps

5/32 90 - 150 Amps
3/16 150 - 250 Amps

ARC GOUGING

The RANGER® 225 can be used for limited arc goug-
ing.

Set the Range switch to adjust output current to the
desired level for the gouging electrode being used
according to the ratings in the following table:

*

When welding with MIG wire instead of self-shielded core wire, weld starts can be improved by setting the idle
mode to “HIGH”.

STICK

No

AUTO

Hot

Touch electrode to work.
Welding starts immediately
and engine goes to high
idle.

WIRE FEED, LN-25 WITH

No

AUTO

Cold

Press gun trigger, LN-25

INTERNAL CONTACTOR

contactor closes. Welding
starts immediately and
engine goes to high idle.
Note: Output Control
must be set above “3”.

*

TIG, TIG MODULE WITH

Yes

HIGH

Cold

Press Amptrol,

WITH CONTACTOR KIT

contactor closes,

CONTROL CABLE, &

welding starts immediately.

AMPTROL

WIRE FEED, LN-15

No

AUTO

Cold

Press gun trigger.

ACROSS the ARC

LN-15 contactor closes,

(has internal contactor)

Welding starts immediately
and engine goes to “HIGH”
Idle.
Note: Output Control must