Installation, Technical specifications - power wave® s350ce – Lincoln Electric IM10029 POWER WAVE S350CE User Manual
Page 10

A-1
INSTALLATION
POWER WAVE® S350CE
A-1
TECHNICAL SPECIFICATIONS - POWER WAVE® S350CE
RECOMMENDED INPUT WIRE AND FUSE SIZES
1
INPUT
VOLTAGE / PHASE/
FREQUENCY
230/3/50/60
380-415/3/50/60
460/3/50/60
575/3/50/60
TIME DELAY FUSE OR
BREAKER
2
AMPERAGE
45
30
25
20
CORD SIZE
3
AWG SIZES (mm
2
)
8 (10)
12 (4)
12 (4)
14 (2.5)
MAXIMUM
INPUT AMPERE RATING
AND DUTY CYCLE
35A, 40%
19A, 40%
17A, 40%
14A, 40%
RATED OUTPUT
POWER SOURCE-INPUT VOLTAGE AND CURRENT
Model
K2823-2
Duty Cycle
40% rating
100% rating
300
Amps
29
Volts
350
Amps
31.5
Volts
320
Amps
30
Volts
INPUT
VOLTAGE / PHASE /
FREQUENCY
230/3/50/60
380-415/3/50/60
460/3/50/60
575/3/50/60
Input Amperes
35/20/17/14
28/16/14/11
Idle Power
300 Watts Max.
(fan on)
Power Factor @
Rated Output
.95
Input Voltage ± 10%
230/380-415/
460/575
50/60 Hz
1. Based on U.S. National electrical Code
2. Also called " inverse time" or "thermal / magnetic" circuit breakers; circuit breakers that have a delay in trip-
ping action that decreases as the magnitude of the current increases
3. Type SO cord or similar in 30° C ambient
GMAW
40%
60%
60%
100%
250
Amps
30
Volts
325
Amps
33
Volts
275
Amps
31
Volts
SMAW
40%
100%
300
Amps
22
Volts
350
Amps
24
Volts
325
Amps
23
Volts
GTAW-DC
40%
60%
100%