A-3

INSTALLATION

PLASMA 20

A-3

Use of normal 20 amp household breakers may result
in over current trips. If breaker trips occur, reduce the
cutting current output until nuisance trips stop.

COMPRESSED AIR OR GAS INPUT
CONNECTION

A source of clean, dry air or nitrogen must be supplied
to the PLASMA 20. Oil in the air is a severe problem
and must be avoided. The supply pressure must be
between 72.5 and 150 psi (5 and 10.3 bar). The flow
rate is approximately 3.5 cu. ft./min. (100L/min.).
Failure to observe these precautions could result in
excessive operating temperatures or damage to the
torch.

Air with considerable quantity of humidity or oil
may cause an excessive wear of the parts or even
damage the torch.

If there are any doubts about the quality of the
compressed air available, it is suggested that an
air dryer be installed before the input filter

.

Using

flexible airline, connect the compressed air to the
rear of the machine. Do not exceed maximum
entry pressure of 150 PSI (10.3 Bar). The pressure
must be adjusted to 72.5 PSI (5 Bar), minimum.

-----------------------------------------------------------------

• To use the air fitting supplied with the machine apply

teflon tape to the fitting threads and install the fitting in
the port at the rear of the machine.

NOTE: When using nitrogen gas from a cylinder, the

cylinder must have a pressure regulator.

Maximum psi from a nitrogen gas cylinder to
the PLASMA 20 regulator should never
exceed 150 psi (10.3 Bar).

Install a hose between the nitrogen gas cylin-
der regulator and the PLASMA 20 gas inlet.

CYLINDER could explode if damaged.

Keep cylinder upright and

chained to a fixed support.

• Keep cylinder away from areas

where it could be damaged.

• Never lift machine with cylinder attached.
• Never allow the cutting torch to touch the cylin-

der.

• Keep cylinder away from live electrical parts.
• Maximum inlet pressure 150 PSI (10.3 Bar).
__________________________________________

CONNECTION TO GROUND CABLE

Connect the work cable clamp to the piece to be cut
or to the metallic workbench. Take the following pre-
cautions:

Verify that there is a good electrical contact particular-
ly if insulated or oxidated coated sheets are cut.

Make ground connections as close as possible to the
cutting area. The use of the metallic structures which
are not part of the workpiece, such as return cable of
the cutting current, may endanger the safety system
and give poor cutting results.

Do not make a ground connection on the piece which
is to be cut off.

TORCH CONNECTION

Before starting the cutting operations verify that
the parts are properly assembled by inspecting
the head of the torch as shown in the “Operations
Section”(Torch Consumable Parts).
------------------------------------------------------------------------
Read and understand this entire section before oper-
ating the machine.

WARNING

WARNING