8.1

Indications on Display

Indication light

Cause

Remedy

Green LED

ON

>

Appliance ready for operation.
When switching on, all the LEDs
light up once.

Yellow LED

ON

>

Fuel shortage

Top up with fuel
Cold water operation possible

Red LED

flashing

>

Service interval: Service due in
20 hours

Contact Nilfisk-ALTO Service

Red LED

ON

>

Service interval expired

Contact Nilfisk-ALTO Service

Red LED

ON

>
>

Pump oil low
Engine oil low


Top up with pump oil
Top up with engine oil

Green LED

flashing

>

Flow sensor failure

Contact Nilfisk-ALTO Service
Cold water operation possible

>

Water tap closed or water
shortage

Required volume flow and pres-
sure see section 9.4 Technical
Specifications

>

Machine scaled

Contact Nilfisk-ALTO Service

Green LED

and red LED

flash simultaneously

>

Leakage or inadmissible opera-
ting condition by short-time
operation

After three times of short-time
ope ration the heating switches
off. Reset: Turn main switch to
position “OFF“, then start again.
Keep spray gun pressed for lon-
ger than 3 seconds. If a leak oc-
curs causing the machine to start
and stop briefly 3 times, then the
heating will switch off.

>

Spray handle leaking

Check spray handle

>

High pressure hose, coupling or
line system leaking

Replace high-pressure hose,
retighten screw fittings

>

Water inlet filter dirty

Clean filter (see section 7.2.1)

>

High-pressure pump drawing in
air

Repair leaks
Cold water operation possible

Red LED

ON

>

Charging rate too low

Engine has not started

Generator defective

Contact Nilfisk-ALTO Service

Red LED

ON

>

Pump overheated

Let pump cool down, avoid long
by-pass time (NEPTUNE 5-46/
5-54 PE, see section 4.2)

>

Engine cooling water overheated
(Mitsubishi)

Check water level in radiator

Green LED

and red LED

flash alternately

>

Overheating failure

Contact Nilfisk-ALTO Service.