beautypg.com

4 jp6: com2 mode select jumper settings, Table 4-4: com2 mode select jumper settings – IEI Integration AFL-07A 08AH 10A 12A-LX Series User Manual

Page 74

background image

AFOLUX LX Series Flat Panel PC

Page 60

4.5.4 JP6: COM2 Mode Select Jumper Settings

The COM2 can be selected as RS-232 or RS-485.

JP6 Description

Short 1-2

RS-232

Default

Short 2-3

RS-485

Short 4-5

RS-232

Default

Short 5-6

RS-485

Short 7-8

RS-232

Default

Short 8-9

RS-485

Short 10-11

RS-232

Default

Short 11-12

RS-485

Table 4-4: COM2 Mode Select Jumper Settings