beautypg.com

3 sata drive connection, Figure 4-12: iris module installation – IEI Integration SPCIE-C2260-i2 User Manual

Page 76

background image

SPCIE-C2260-i2 PICMG 1.3 CPU Card

Page 59

Figure 4-12: iRIS Module Installation

Step 1:

Locate the iRIS module slot. Place the SPCIE-C2260-i2 on an anti-static pad.

Step 2:

Align the iRIS-2400 module with the iRIS module slot. Align the notch on the

module with the notch on the iRIS module slot.

Step 3:

Insert the iRIS-2400 module. Push the module in at a 20º angle (Figure 4-12).

Step 4:

Seat the iRIS-2400 module. Gently push downwards and the arms clip into

place (Figure 4-12).

Step 0:

NOTE:

After installing the iRIS-2400 module, use LAN2 port to establish a

network connection. Please refer to Section 4.8 for IPMI setup

procedures.

4.5.3 SATA Drive Connection

The SPCIE-C2260-i2 is shipped with two SATA drive cables. To connect the SATA drives

to the connectors, please follow the steps below.

Step 1:

Locate the connectors. The locations of the SATA drive connectors are shown

in Chapter 3.